Article

DOI 10.17586/0021-3454-2020-63-9-794-802

UDC 62-50

CALCULATION OF A DIGITAL TRACKING SYSTEM WITH A FINITE DECAY TIME OF A FREE PROCESS. PART II. TRANSITION TIME EXCEEDING MINIMUM

A. . Konovalov
Naval Polytechnic Institute of Military educational and scientific center of the Navy "Naval Academy named after Admiral of the Fleet of the Soviet Union N.G. Kuznetsov", Faculty of Control Systems Automation;


A. I. Korshunov
Popov Navy Institute of Radioelectronics, Department of Radioelectronics, St. Petersburg; Professor


Read the full article 

Abstract. Two methods for selecting the transfer function of a discrete correction filter are considered. With a simpler method, the control effect is significantly reduced, but the speed error increases. A more complex method of correction filter selection enables the speed error retention, as in the case of minimum damping time of the free process, but with a less significant reduction in the control effect and a small overshoot when working out the jump. An example of digital tracking system calculating is given. Numerical simulation of the calculated CSR in the MatLab system is performed for linearly increasing and stepwise reference signals. The simulation data are reported to coincide with the calculated results.
Keywords: digital tracking system, free process decay, transition time exceeding minimum

References:
  1. Konovalov A.M., Korshunov A.I. Journal of Instrument Engineering, 2020, no. 9(63), pp. 786–793. (in Russ.)
  2. Korshunov A.I. Journal of Instrument Engineering, 2019, no. 12(62), pp. 1078–1086. (in Russ.)
  3. Isermann R. Digital control sуstems, Berlin etc., 1981.
  4. Jury E.J. Sampled-data control systems, NY, Wiley, London, Chapmen and Hall, 1958.
  5. Shipillo V.P. Operatorno-rekurrentnyy metod rascheta elektricheskikh tsepey i sistem (Operator-Recurrence Method for Calculating Electrical Circuits and Systems), Moscow, 1991, 311 р. (in Russ.)