Preview

Journal of Instrument Engineering

Advanced search
Open Access Open Access  Restricted Access Subscription Access

Spectral Sensitivity Calibration Setup for Spectro Analytical Instruments

https://doi.org/10.17586/0021-3454-2026-69-2-151-157

Abstract

An installation for calibrating the spectral sensitivity of a spectroanalytical instrument (SAP) is presented. The special feature of the installation is that a set of narrow-spectrum radiation fluxes enters the SAP. The developed optical scheme of the calibration radiation source included in the installation makes it possible to obtain a set of such radiation fluxes. The fluxes were measured by a reference photodetector precisely at the SAP inlet, which eliminated the need to take into account the influence of medium transmission on the measurement results.

About the Authors

A. V. Ilinskii
ITMO University
Russian Federation

Alexander V. Ilinskii — Vice-Director of the Scientific Educational Center “ITMO University History Museum",

St. Petersburg.



N. K. Maltseva
ITMO University
Russian Federation

Nadezhda K. Maltseva — PhD; Director of the Scientific Educational center “ITMO University History Museum”, 

St. Petersburg.



E. O. Raskin
ITMO University
Russian Federation

Eugene O. Raskin —Director of Youth Policy,

St. Petersburg.



References

1. Titov D.V. Journal of Instrument Engineering, 2010, no. 9(53), pp. 80–83. (in Russ.)

2. Eckart M., Adams J., Boyce K. et al. Proc. SPIE, Telescopes and Instrumentation 2016: Ultraviolet to Gamma Ray, 2016, vol. 9905, Space, рр. 99053W, DOI: 10.1117/12.2233053.

3. Yao Li et al. Opt. Express, 2025, no. 2(33), pp. 3400–3413, DOI: 10.1364/OE.549749.

4. Osipov V.M. and Borisova N.F. Journal of Optical Technology, 2019, no. 8(86), pp. 471–475, https://doi.org/10.1364/JOT.86.000471.

5. Torshina I. P. Journal of Instrument Engineering, 2008, no. 9, pp. 37‒40. (in Russ.)

6. Ilinsky A.V., Maltseva N.K., Raskin E.O. Journal of Instrument Engineering, 2026, no. 1(69), pp. 49–59. (in Russ.)

7. Mushenkov A.V. Difraktsionnyy monokhromator MDR-23 s registratsiyey na FEU (Diffraction Monochromator MDR-23 with Registration on a Photomultiplier), Moscow, 2022, 18 р. (in Russ.)

8. Il’inskiǐ A.V., Mal’tseva N.K. Journal of Optical Technology, 2010, no. 2(77), pp. 137–140.

9. Ilyinsky A.V., Mal’tseva N.K., Raskin E.O. Scientific and Technical Journal of Information Technologies, Mechanics and Optics, 2025, no. 6(25). Р. 1024–1032. (in Russ.)


Review

For citations:


Ilinskii A.V., Maltseva N.K., Raskin E.O. Spectral Sensitivity Calibration Setup for Spectro Analytical Instruments. Journal of Instrument Engineering. 2026;69(2):151-157. (In Russ.) https://doi.org/10.17586/0021-3454-2026-69-2-151-157

Views: 192

JATS XML

ISSN 0021-3454 (Print)
ISSN 2500-0381 (Online)