ISSN 0021-3454 (print version)
ISSN 2500-0381 (online version)
Menu

10
Issue
vol 67 / October, 2024
Article

DOI 10.17586/0021-3454-2018-61-8-734-737

UDC 621.373.826:535.21

OPTIMUM MODE FOR PROCESSING CATARACT LENS OF THE HUMAN EYE WITH MICROSECOND PULSES OF Yb, Er: GLASS LASER

A. V. Belikov
ITMO University, Saint Petersburg, 197101, Russian Federation; Pavlov University, Saint Petersburg, 197022, Russian Federation; Full Professor; Senior Researcher


A. M. Zagorulko
St. Petersburg Branch of the S. Fyodorov Eye Microsurgery Federal State Institution; Medical Director


S. N. Smirnov
ITMO University, Saint Petersburg, 197101, Russian Federation; Assistant, Leading Engineer


Read the full article 

Abstract. Results of the study of removal efficiency of cataract-affected lens of the eye under the action of microsecond pulses of Yb, Er: Glass-laser are presented. The efficiency of lens removal is discussed in relation to the number of laser pulses, their energy, as well as the distance between the end of the optical fiber and the surface of the bioobject.
Keywords: Yb,Er:Glass-laser, microsecond pulses, lens of the eye, removal efficiency, cataract extraction, fiber

References:
1. Kopayeva V.G., Andreyev Yu.V. Lazernaya ekstraktsiya katarakty (Laser Extraction of a Cataract), Moscow, 2011, 262 р. (in Russ.)
2. Belikov A.V., Gagarskiy S.V., Gubin A.B., Vayner C.Ya., Sergeyev A.N., Smirnov S.N. Scientific and Technical Journal of Information Technologies, Mechanics and Optics, 2015, no. 6(15), pp. 1021–1029. DOI: 10.17586/2226-1494-2015-15-6-1021-1029
3. Kopayev S.Yu., Malyugin B.E., Kopayeva V.G. Tomsk State University Journal, 2015, no. 3(20), pp. 619–622. (in Russ.)
4. Buratto L., Werner L., Apple D. J., Zanini M. Phacoemulsification: Principles and Techniques, 2nd ed. SLACK Incorporated, 2003, 754 p.
5. Belikov A.V., Gagarskiy S.V., Sergeev A.N., Smirnov S.N. Journal of Instrument Engineering, 2017, no. 4(60), pp. 367–374. DOI: 10.17586/0021-3454-2017-60-4-367-374
6. Belikov A.V., Fomicheva Y.Y., Gagarskiy S.V., Sergeev A.N., Smirnov S.N., Zagorulko A.M. Proc. SPIE, 2018, vol. 10716, рр. 107160W, DOI: 10.1117/12.2307238.
7. Kopayev S.Yu. Kliniko-eksperimental’noye obosnovaniye kombinirovannogo ispol’zovaniya neodimovogo IAG 1.44 mkm i geliy-neonovogo 0.63 mkm lazerov v khirurgii katarakty (Clinical and Experimental Study of the Combined Use of a Neodymium YAG 1.44 μm and a He-Ne 0.63 μm Laser in Cataract Surgery), Doctor’s thesis, Moscow, 2014. (in Russ.)